Glen
January 10, 2024
Help - we like this CHINESE made microwave, BUT it blew the breaker when closing the door. I suspect it is a switch. Can you advise and provide the part number??
For model number HMV5053U /01
Hi Glen, thank you for contacting us. We have found that your model has 3 door switches. The 2 door switches are part number PS8728111, and the interlock switch is part number PS8728112. Glad to be of help!
didnt get anything with it.need need template and screw etc.
For model number HMV5053U
Hi Sandra, thank you for the question. The mounting set for your model is part number PS10058322, and the templates are part number PS11728990, and PS8724779. We hope that helps!
Unplug microwave. Removed 2 screws from the top of the microwave to remove the top plastic strip carefully because the tabs can break off. Remove one screw above the control panel and one screw underneath the control panel. The control panel should come out. Take a picture of the wiring connections to help identify how to put it back toge
... Read morether. Carefully disconnect each wire set using a needle nose plier if needed. There are 3 sets of wires that go to the 3 door switches. After the control panel is removed there are 2 or three screws to remove that hold the door latch mechanism. With the door open, entirely remove the latch mechanism. Pay attention to the 3 switches, one has a different number on it and the other two have the same number but differ by being normally closed and normally open. You can test them or just replace them. Note I ordered the 3 switches by part number but got 1 switch that was incorrect and was the same as the other one. There is a plastic tab that needs to be depressed at the bottom of the switch casing in order to get the switch out. The problem with my microwave ended up being the lever was worn visibly by door misalignment with the latch. One of the screws holding the latch in position was missing. The door was not consistently activating the lever and the bottom switch. Replaced the latch, lever and two of the 3 switches, even though they didn’t need it. Check door alignment with latch. Reassemble.
Replaced fuse and switches.This is an undercabinet microwave. The fuse is located in top right but there is no access from the front of the microwave necessitating complete removal of the microwave from the cabinets and then taking the microwave cover off. This is a terrible design, Instead, I cut the vent grate on the top
... Read moreright front of the microwave to access the fuse. replaced the fuse. Switches were relatively easy to replace...being careful to not pull wires out of connectors or breaking small plastic tongs and clips. Microwave is still blowing fuses though. door alignment may be off. Again, terrible design and lousy product quality.